v2 Specimen role
activeContentcompleteURL
http://terminology.hl7.org/CodeSystem/v2-0369Copied!
Version2.9Copied!
PublisherHL7, IncDescriptionFHIR Value set/code system definition for HL7 v2 table 0369 ( Specimen role)
Concepts
Select a concept to view details
Specimen Role
{
"description" : "FHIR Value set/code system definition for HL7 v2 table 0369 ( Specimen role)",
"meta" : {
"profile" : [ "http://hl7.org/fhir/StructureDefinition/shareablecodesystem" ]
},
"publisher" : "HL7, Inc",
"content" : "complete",
"property" : null,
"name" : "v2.0369",
"experimental" : false,
"resourceType" : "CodeSystem",
"title" : "v2 Specimen role",
"extension" : [ {
"valueCode" : "external",
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"
}, {
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger" : 0
}, {
"extension" : [ {
"valueString" : "concept",
"url" : "path"
}, {
"url" : "count",
"valueInteger" : 11
} ],
"url" : "http://health-samurai.io/extensions/excised-data"
}, {
"url" : "http://health-samurai.io/extensions/source",
"valueCode" : "db"
} ],
"status" : "active",
"language" : "en",
"id" : "2ed18f64-17dd-4318-af26-1ca8ac30dd64",
"url" : "http://terminology.hl7.org/CodeSystem/v2-0369",
"identifier" : [ {
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.18.227"
} ],
"version" : "2.9",
"contact" : [ {
"telecom" : [ {
"system" : "url",
"value" : "http://hl7.org"
} ]
} ],
"text" : {
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <p>Specimen Role</p>\n\n <table class=\"grid\">\n <tr>\n <td>\n <b>Code</b>\n </td>\n <td>\n <b>Description</b>\n </td>\n <td>\n <b>Comment</b>\n </td>\n <td>\n <b>Version</b>\n </td>\n </tr>\n <tr>\n <td>B\n <a name=\"B\"> </a>\n </td>\n <td>Blind Sample</td>\n <td/>\n <td>added v2.4</td>\n </tr>\n <tr>\n <td>C\n <a name=\"C\"> </a>\n </td>\n <td>Calibrator, used for initial setting of calibration</td>\n <td/>\n <td>added v2.4</td>\n </tr>\n <tr>\n <td>E\n <a name=\"E\"> </a>\n </td>\n <td>Electronic QC, used with manufactured reference providing signals that simulate QC results</td>\n <td/>\n <td>added v2.5</td>\n </tr>\n <tr>\n <td>F\n <a name=\"F\"> </a>\n </td>\n <td>Specimen used for testing proficiency of the organization performing the testing (Filler)</td>\n <td/>\n <td>added v2.5</td>\n </tr>\n <tr>\n <td>G\n <a name=\"G\"> </a>\n </td>\n <td>Group (where a specimen consists of multiple individual elements that are not individually identified)</td>\n <td/>\n <td>added v2.5</td>\n </tr>\n <tr>\n <td>L\n <a name=\"L\"> </a>\n </td>\n <td>Pool (aliquots of individual specimens combined to form a single specimen representing all of the components.)</td>\n <td/>\n <td>added v2.5</td>\n </tr>\n <tr>\n <td>O\n <a name=\"O\"> </a>\n </td>\n <td>Specimen used for testing Operator Proficiency</td>\n <td/>\n <td>added v2.5</td>\n </tr>\n <tr>\n <td>P\n <a name=\"P\"> </a>\n </td>\n <td>Patient (default if blank component value)</td>\n <td/>\n <td>added v2.4</td>\n </tr>\n <tr>\n <td>Q\n <a name=\"Q\"> </a>\n </td>\n <td>Control specimen</td>\n <td/>\n <td>added v2.4</td>\n </tr>\n <tr>\n <td>R\n <a name=\"R\"> </a>\n </td>\n <td>Replicate (of patient sample as a control)</td>\n <td/>\n <td>added v2.4</td>\n </tr>\n <tr>\n <td>V\n <a name=\"V\"> </a>\n </td>\n <td>Verifying Calibrator, used for periodic calibration checks</td>\n <td/>\n <td>added v2.5</td>\n </tr>\n </table>\n\n </div>",
"status" : "additional"
}
}